一、福州地暖保溫系統施工準備:
做地(di)面(mian)保溫(wen)系統鋪(pu)設(she)前應保證(zheng)土建地(di)面(mian)墻(qiang)(qiang)體(ti)均已(yi)完工(gong)(gong),并(bing)做過基礎找平,場(chang)地(di)內(nei)(nei)(nei)無其他(ta)工(gong)(gong)種(zhong)在施工(gong)(gong)。施工(gong)(gong)室內(nei)(nei)(nei)溫(wen)度(du)應該符合所用(yong)(yong)管(guan)材要求(qiu)合理使(shi)用(yong)(yong)溫(wen)度(du),因(yin)為環境溫(wen)度(du)和(he)管(guan)材的彎曲(qu)半徑有(you)密切關(guan)系。清掃地(di)面(mian)和(he)墻(qiang)(qiang)體(ti),使(shi)用(yong)(yong)水(shui)平尺校對地(di)面(mian)平整度(du),1米以內(nei)(nei)(nei)高低差小于或(huo)等于5毫米。墻(qiang)(qiang)面(mian)或(huo)地(di)面(mian)凸出部分用(yong)(yong)鐵鏟(chan)鏟(chan)除,用(yong)(yong)混凝(ning)土填充地(di)面(mian)坑槽。衛(wei)生間和(he)別(bie)墅底層應該做好(hao)防(fang)水(shui)層或(huo)者鋪(pu)設(she)防(fang)潮膜。
二(er)、地暖(nuan)專用邊(bian)界(jie)保溫(wen)條施工
鋪設邊界保(bao)(bao)溫(wen)條(tiao)(tiao)之前要清掃墻(qiang)體(ti),保(bao)(bao)證(zheng)墻(qiang)面(mian)(mian)的(de)(de)平整(zheng)度,避免保(bao)(bao)溫(wen)條(tiao)(tiao)在(zai)(zai)施工和使用(yong)(yong)的(de)(de)過程中脫(tuo)落。邊界保(bao)(bao)溫(wen)條(tiao)(tiao)應(ying)(ying)該粘(zhan)(zhan)貼(tie)在(zai)(zai)供暖區(qu)域內所有(you)與地(di)面(mian)(mian)相(xiang)交(jiao)處(chu)的(de)(de)墻(qiang)面(mian)(mian)和柱面(mian)(mian)上,邊界保(bao)(bao)溫(wen)條(tiao)(tiao)要具有(you)優異的(de)(de)粘(zhan)(zhan)貼(tie)牢度保(bao)(bao)證(zheng)其使用(yong)(yong)中不(bu)會脫(tuo)落。邊界保(bao)(bao)溫(wen)條(tiao)(tiao)具有(you)8毫米的(de)(de)厚(hou)度,邊界保(bao)(bao)溫(wen)條(tiao)(tiao)要具有(you)一定的(de)(de)伸縮性能,保(bao)(bao)證(zheng)回填層蓄熱膨脹后起到緩沖的(de)(de)作用(yong)(yong),***限(xian)度的(de)(de)壓縮量為5毫米。切割的(de)(de)擠塑板不(bu)允許替代邊界保(bao)(bao)溫(wen)條(tiao)(tiao)。邊界保(bao)(bao)溫(wen)條(tiao)(tiao)連接(jie)處(chu)應(ying)(ying)使用(yong)(yong)搭接(jie),且搭接(jie)長度不(bu)少于3公分。
三、 地暖專用環保(bao)擠塑板(ban)鋪(pu)設(she)
擠(ji)塑板在鋪設(she)之前要保(bao)證原(yuan)始地面(mian)層的(de)平整度(du)(du)。擠(ji)塑板應選(xuan)(xuan)擇密(mi)度(du)(du)、抗(kang)壓強度(du)(du)、導熱系數均能(neng)達到地采(cai)暖技術規程里要求指標。常規區(qu)域(yu)鋪設(she)擠(ji)塑板選(xuan)(xuan)用2公(gong)分(fen)厚(hou)度(du)(du)即可,對于潮濕環(huan)境或者(zhe)保(bao)溫性(xing)差的(de)區(qu)域(yu)應選(xuan)(xuan)用大于2公(gong)分(fen)的(de)厚(hou)度(du)(du)。
四、 地暖專用反(fan)射層鋪設
由于反(fan)(fan)射(she)膜(mo)(mo)的(de)(de)(de)使用環境,在選(xuan)擇反(fan)(fan)射(she)膜(mo)(mo)的(de)(de)(de)時(shi)候(hou)應選(xuan)擇耐(nai)堿性(xing)強(qiang)的(de)(de)(de)產品。反(fan)(fan)射(she)膜(mo)(mo)的(de)(de)(de)鋪設要(yao)(yao)平整(zheng),盡量(liang)減(jian)少褶皺。反(fan)(fan)射(she)膜(mo)(mo)鋪設應遮蓋嚴(yan)密(mi),不得有(you)保溫板和地面漏鋪現象。反(fan)(fan)射(she)膜(mo)(mo)鋪設應注意方格整(zheng)齊,方便計算地暖(nuan)管(guan)或發(fa)熱電纜的(de)(de)(de)間(jian)距。 反(fan)(fan)射(she)膜(mo)(mo)連接處也要(yao)(yao)使用鋁箔膠帶粘連,避(bi)免搭接過多造成材(cai)料(liao)浪費。
五(wu)、 地暖專(zhuan)用卡(ka)丁施工
不(bu)可(ke)使用回(hui)收(shou)料制(zhi)造出來的卡(ka)(ka)釘(ding)(ding),對人體有害。卡(ka)(ka)釘(ding)(ding)的材質需(xu)要(yao)(yao)(yao)滿足高強度(du)和良好蠕(ru)變性能的基本要(yao)(yao)(yao)求(qiu)(qiu)。借助卡(ka)(ka)釘(ding)(ding)槍施工的卡(ka)(ka)釘(ding)(ding)強度(du)要(yao)(yao)(yao)求(qiu)(qiu)更高,可(ke)承受機械安(an)裝(zhuang)。直線距離卡(ka)(ka)釘(ding)(ding)可(ke)以每隔(ge)40-50CM卡(ka)(ka)一次,轉彎處確(que)保彎曲半徑要(yao)(yao)(yao)求(qiu)(qiu)應該使用5個卡(ka)(ka)丁(ding)固定(ding)。卡(ka)(ka)釘(ding)(ding)安(an)裝(zhuang)時注意要(yao)(yao)(yao)筆直卡(ka)(ka)入保溫(wen)層(ceng),切忌傾斜卡(ka)(ka)釘(ding)(ding)以免(mian)固定(ding)效果不(bu)佳(jia)。
六、地面管道施(shi)工
根據設(she)計(ji)圖紙進行布管,確定管間(jian)距和管道走向,直管安裝間(jian)距誤差小(xiao)于(yu)或(huo)等(deng)于(yu)1cm。管道鋪(pu)(pu)設(she)施(shi)工(gong)(gong)過(guo)程中(zhong)(zhong)盡量穿平(ping)底(di)鞋。一(yi)個(ge)回(hui)(hui)(hui)路不(bu)應該出現接頭,鋪(pu)(pu)設(she)每(mei)個(ge)回(hui)(hui)(hui)路長度(du)也都有(you)限(xian)制(zhi)。16x2.0mm管道一(yi)個(ge)回(hui)(hui)(hui)路***的鋪(pu)(pu)設(she)長度(du)應小(xiao)于(yu)90m;20x2.0mm管道一(yi)個(ge)回(hui)(hui)(hui)路***鋪(pu)(pu)設(she)長度(du)應小(xiao)于(yu)120m。施(shi)工(gong)(gong)中(zhong)(zhong)禁止(zhi)過(guo)度(du)扭曲管道,管道彎(wan)曲處半徑控(kong)制(zhi)在不(bu)應小(xiao)于(yu)6倍管外徑。鋪(pu)(pu)設(she)完成后嚴(yan)禁踩(cai)踏或(huo)其他損傷管道行為,地面回(hui)(hui)(hui)填層施(shi)工(gong)(gong)中(zhong)(zhong)杜絕粗暴野蠻施(shi)工(gong)(gong)。
七、伸縮縫施工
當(dang)地(di)面施工面積大于30平方米或邊長超過6米時,應按不(bu)大于6米的(de)(de)間距設置(zhi)伸(shen)縮(suo)縫(feng),每個(ge)過門處設置(zhi)伸(shen)縮(suo)縫(feng),復雜(za)房(fang)型可以劃(hua)區分(fen)割計算。伸(shen)縮(suo)縫(feng)高度是(shi)從擠(ji)塑板上(shang)邊緣到回填(tian)層(ceng)的(de)(de)上(shang)邊緣,伸(shen)縮(suo)縫(feng)設置(zhi)處的(de)(de)地(di)暖管(guan)(guan)需要加(jia)套保溫管(guan)(guan)。地(di)面如果(guo)鋪設的(de)(de)是(shi)大理(li)石或瓷磚(zhuan),伸(shen)縮(suo)縫(feng)***設置(zhi)在瓷磚(zhuan)拼縫(feng)的(de)(de)下面。
八(ba)、 地暖專用生(sheng)料(liao)帶(dai)施(shi)工
螺紋連接(jie)處應(ying)使用(yong)生料(liao)帶以達到優質的密封效(xiao)果。生料(liao)帶纏(chan)(chan)繞(rao)圈(quan)數(shu)不宜過多,防(fang)止對連接(jie)件造成損壞。地采暖(nuan)專用(yong)生料(liao)帶其密度(du)和(he)厚度(du)高于市售生料(liao)帶,生料(liao)帶施工時要順(shun)時針纏(chan)(chan)繞(rao),絲口的纏(chan)(chan)繞(rao)厚度(du)一(yi)般由(you)厚到薄(bo)。
九、地暖專(zhuan)用彎管(guan)器和保溫管(guan)施工
地(di)暖分(fen)(fen)水(shui)器(qi)距離地(di)面有一(yi)定高度,管道由分(fen)(fen)集水(shui)器(qi)進入地(di)面部(bu)分(fen)(fen)一(yi)般要使(shi)用(yong)保(bao)護彎管器(qi),起到(dao)固(gu)定和(he)保(bao)護地(di)面盤管不被破壞。
切不(bu)(bu)可不(bu)(bu)用(yong)或(huo)使用(yong)金(jin)屬彎管器(qi)(qi),造(zao)成更大(da)程(cheng)度(du)(du)的(de)損傷管道(dao)(dao)(dao),推薦使用(yong)強度(du)(du)較(jiao)高的(de)塑料彎管器(qi)(qi)。分水(shui)器(qi)(qi)處(chu)裸露(lu)在外的(de)供(gong)回水(shui)管道(dao)(dao)(dao)需使用(yong)保(bao)(bao)(bao)溫(wen)套管。分水(shui)器(qi)(qi)處(chu)地(di)面下地(di)暖(nuan)管道(dao)(dao)(dao)密集,為(wei)防止局(ju)部溫(wen)度(du)(du)過高應使用(yong)保(bao)(bao)(bao)溫(wen)套管。一般加套在供(gong)水(shui)管道(dao)(dao)(dao)上,回水(shui)是否加套需根據該(gai)路管道(dao)(dao)(dao)長度(du)(du)而定(ding)。保(bao)(bao)(bao)溫(wen)套管的(de)使用(yong)長度(du)(du)至兩管之(zhi)間(jian)間(jian)距大(da)于(yu)10公(gong)分處(chu)。每路管道(dao)(dao)(dao)都應該(gai)配彎管器(qi)(qi),保(bao)(bao)(bao)溫(wen)套管與之(zhi)隔開使用(yong)。
十、混凝土回填(tian)層施工
混凝(ning)(ning)土回填層(ceng)的(de)厚度一般在3-5CM左右,***不應(ying)小(xiao)于3CM。回填層(ceng)的(de)混凝(ning)(ning)土配比(bi)應(ying)嚴(yan)格(ge)執(zhi)行《普通混凝(ning)(ning)土用砂(sha)、石質量(liang)和檢測方法標準(zhun)》的(de)比(bi)例標準(zhun)。地(di)暖加(jia)熱管安裝完畢且水(shui)壓(ya)試驗(yan)合(he)格(ge)后 48 小(xiao)時內完成(cheng)混凝(ning)(ning)土填充(chong)層(ceng)施工。混凝(ning)(ning)土填充(chong)層(ceng)施工中(zhong), 嚴(yan)禁(jin)使用機械振(zhen)搗設備;施工人員應(ying)穿軟(ruan)底鞋,采用平頭鐵鍬(qiao)。